EKey Fingerscan Access Control System Instrukcja Instalacji Strona 37

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 64
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 36
(941) 782-1227
info@ekeyUSA.com
ekeyUSA Catalog
2013
ekeyusa_catalog_2012_v7
5.2.1 ekey net Wall Mount Control Unit Wiring Diagram Layout
CLAMP
FUNCTION
1
RS485 data bus (Green color wire in cable A for the integra scanner)
2
RS485 data bus (Yellow color wire in cable A for the integra scanner)
Channel 1
Dry contact (not energized - Form C) switch #1 Form C Relay Common (C), Normal Open
(NO), Normal Close (NC)
Channel 2
Dry contact switch #2 Common (C), Normal Open (NO), Normal Close (NC)
Channel 3
Dry contact switch #3 Common (C), Normal Open (NO), Normal Close (NC)
3
Power supply for the scanner (Brown color wire in cable A for the integra scanner)
4
Power supply for the scanner (White color wire in cable A for the integra scanner)
9VAC
Main Power supply for the control unit
Dry contact means no voltage is provide by ekey system on the relay. Form C contacts are also called
changeover contacts that have three contacts as follows:
1. (C) Common = common leg of the circuit
2. (NO) Normal Open = default relay is open meaning the circuit is open not complete; relay will close to
complete the circuit when a valid fingerprint match is found. For example, this option is used when
controlling door with electrical strike in Fail-Secure mode. In this scenario the door is closed when the lock
has no power. When a valid fingerprint match is found, the relay is closed causing the lock to energized
leading to the door to set open.
3. (NC) Normal Close = default relay is closed meaning the circuit is closed and complete; relay will open to
break the circuit when a valid fingerprint match is found. For example, this option is used when controlling
door with Magnetic Lock or electrical strike in Fail-Safe mode. In this scenario the lock requires power to
magnetize and hold the door close. When a valid fingerprint match is found, the relay is opened causing the
lock to lose its power and demagnetized leading the door to set open.
Przeglądanie stron 36
1 2 ... 32 33 34 35 36 37 38 39 40 41 42 ... 63 64

Komentarze do niniejszej Instrukcji

Brak uwag