Clamp
Function
1
RS485 data bus (Green color wire in cable A for the integra scanner)
2
RS485 data bus (Yellow color wire in cable A for the integra scanner)
Channel 1
Dry contact (Form C ) sw it ch # 1 F orm C Rel ay Common (C), Normal Open (NO), Normal
Close (NC)
Channel 2
Dry contact switch #2Common (C), Normal Open (NO), Normal Close (NC)
Channel 3
Dry contact switch #3Common (C), Normal Open (NO), Normal Close (NC)
3
Power supply for the scanner (Brown color wire in cable A for the integra scanner)
4
Power supply for the scanner (White color wire in cable A for the integra scanner)
9VAC
Main Power supply for the control unit
Dry contact (not energized) means no voltage is provide by ekey system on the relay. Form C contacts are also
called changeover contacts that have three contacts as follows:
1. (C) Common = common leg of the circuit
2. (NO) Normal Open = default relay is open meaning the circuit is open not complete; relay will close to
complete the circuit when a valid fingerprint m at ch is found. For example, this option is used when
controlling door with electrical strike in Fail-Secure mode. In this scenario the door is closed when the lock
has no power. When a valid fingerprint match is found, the relay is closed causing the lock to energized
leading to the door to set open.
3. (NC) Normal Close = default relay is closed meaning the circuit is closed and complete; relay will open to
break the circuit when a valid fingerprint match is found. For example, this option is used when controlling
door with Magnetic Lock or electrical strike in Fail-Safe mode. In this scenario the lock requires power to
magnetize and hold the door close. When a valid fingerprint match is found, the relay is opened causing t h e
lock to lose its power and demagnetized leading the door to set open.