7
ekey multi wiring
OntherstandthelastdeviceintheRS485bus,theterminationswitchhastobeseton„ON“.
optional
First device
in the bus
(chain)
Devices
in the
middle of
the bus
Depending on the
conguration,0to3
units can be
placed here
Last device
in the bus
(chain)
Cable recommendation
J-Y(ST)Y 4 x 2 x 0.8
Wire assignment:
2x RS485 bus; 2x RS485 back-up wires
2x power supply; 2x back-up wires for increased
cross section when cable length is above 50m
RS485: serial
wiring (in a line)
max. 500m
NO STAR-SHAPED
WIRING!
Notebook/PC with
software
ekey FWupdate
CP
DRM
multi
FS WM 2.0
FS OM
FS IN 2.0
FS OM
Up to 4 ekey home nger scanners
connected to 1 ekey multi control panel