© ekey biometric systems GmbH Operating instructions ekey home Page 39 / 41
Error code
„E2“
on the display
The wrong security code
has been
entered three
times. Device is locked for 30 minutes.
Wait 30 minutes before entering the security
code again. The system has to be
permanently powered within those 30 min!
Error code
„E3“
on the display
Device
connected/coupled incorrectly
Re
-
couple the devices
=
initialize devices.
One of the devices has been manipulated.
ekey home
CP DRM
The initialization
process (=
commissioning)
cannot be carried
out.
The control panel cannot reach the finger scanner,
no data exchange possible.
Check, whether the finger scanner is
connected to the mains
(status LED has to
blink in orange).
Check the bus connection (clamp 1 and 2)
between the finger scanner and the control
panel.
Check the device termination (resistor
) acc.
to the wiring diagram.
The message
„Locked for 30
min” is displayed
on the LCD of the
CP DRM.
The wrong security code
has been
entered three
times in a row.
Wait 30 minutes before entering the security
code again. The system has to be
permanently powered within those 30 min!
The d
isplay
of
the CP DRM
reports offline
and the counter
decrements from
44 to 0.
1. No bus connection to the fingerprint scanner
2. The power supply to the system has been
interrupted. The system will be restarted.
1. Check the 4
-
core connection cable
between finger scanner and control panel.
Pay special attention to clamp 1 and 2.
2. Check the power supply on clamp 3 and 4,
it must be at least 8V.
3. Wait until the start process has
been
concluded.
The display
reports during
enrollment
„Already 99
fingers
registered
99 fingerprints have already been registered.
You
cannot enroll more than 99 fingerprints.
Try to delete inactive users.
ekey home
f
inger
scanner
The green LE
D on
the finger scanner
signaliz
es that the
finger has been
positively
recognized, but the
relay does not
switch.
Wrong device allocation (coupling).
Access will not be granted since one of the two
devices has been exchanged.
Re
-
couple the devices.
One of the devices
has been manipulated.
Reset the system to factory settings before
re-initializing them (see section 8.2.1.12)
The status LED of
the finger scanner i
blinking red/green.
The sensor might have been damaged
or may not be
working correctly.
Contact the technical support department.
Please have the serial number of the product
ready (to be found below
the barcode label).
See page 4 for contact details.